Power flow - Drive 4 lock up

In Drive 4 Lock Up, transmission drive is the same as for
Drive 4 but with the application of the converter lock up
clutch to provide positive no-slip converter drive.
Control
To maintain this arrangement in the steady state sole-
noids and valves are activated as follows;
• When S7 is switched ON, S7 feed oil to the converter
clutch control valve is switched OFF and allowed to
exhaust through the S7 solenoid. This allows the valve
to move to the clutch engage position.
Gear State
Drive 4 Lock Up
BTRA 4 AUTO TRANSMISSION
REXTON SM - 2004.4
C1
C2
C3
X
X
-
• Regulated apply feed oil, drived from drive oil at the
converter clutch regulator valve, is directed by the
converter clutch control valve to the engage side of the
converter clutch.
• Converter clutch release oil is exhausted at the con-
verter clutch control valve.
• Converter feed oil is re-routed by the converter clutch
control valve directly to the oil cooler and lubrication
circuit.
ELEMENTS ENGAGED
C4
B1
B2
-
X
-
3A2-37
1-2
3-4
LU
OWC
OWC
CLUTCH
-
-
-
Y220_3A2480
CHANGED BY
EFFECTIVE DATE
AFFECTED VIN