DI10-156

2.5V Supply Voltage Fault

Trouble Code and Symptom
P0698
Low
P0699
High
P0697
Supply Voltage
Diagnosis Procedures
Supply Voltage 1 (5 V):
Accelerator Pedal Sensor 1
"Supply Voltage 2 (5 V): HFM
sensor, Rail pressure
sensor, Boost pressure
sensor and Cam sensor"
Supply Voltage (2.5 V):
Accelerator Pedal Sensor 2
Read DTC
All DTCs for sensors
connected to sensor supply
voltage?
NO
Check wiring
Trouble Continues?
NO
Repair completed
CHANGED BY
EFFECTIVE DATE
AFFECTED VIN
Trouble Code
YES
Sensor problem caused by supply voltage
to sensor. Locate the problem while dis-
connecting the sensor one by one. If not
sensor problem, check wiring.
YES
Replace ECU
Symptom
Unable Cruise Control
DIAGNOSIS
DI ENG SM - 2004.4