Signaling Mode - Lucent Technologies MERLIN LEGEND Release 5.0 System Programming Manual

Communications system
Hide thumbs Also See for MERLIN LEGEND Release 5.0:
Table of Contents

Advertisement

MERLIN LEGEND Communications System Release 5.0
System Programming 555-650-111
4
Programming Procedures
DS1 Facilities
Console/Display Instructions
Select Suppression.
 
DS1 Slot xx :
Make a selection
Type
FrameFormat
Suppression
_
Signaling
Exit
Select AMI zero code suppression or bipolar 8 zero substitution.
 
DS1 Slot xx :
Select one
AMI-ZCS
_
B8ZS
_
Exit
Save your entry.
 
Select
.
Enter
Return to the System Programming menu.
 
Select
twice.
Exit

Signaling Mode

Use this procedure to specify the signaling for the 100D module as robbed-bit or
common-channel signaling.
NOTE:
NOTE:
NOTE:
This procedure is needed only for T1 facilities; common-channel signaling
is set automatically for PRI facilities.
Summary: Signaling Mode
Programmable by
Mode
Idle Condition
Planning Form
Factory Setting
Valid Entries
Additional Information
xx = slot number entered in Step 3
Line Comp
ChannelUnit
xx = slot number entered in Step 3
Select
B8ZS
Enter
System Manager
All
100D module idle
Form 3b, Incoming Trunks: DS1 Connectivity
(100D module)
Robbed bit
Robbed Bit, Common Channel
or
AMI-ZCS
.
4
4
Issue 1
June 1997
Page 4-98