Lucent Technologies MERLIN LEGEND Release 5.0 System Programming Manual page 129

Communications system
Hide thumbs Also See for MERLIN LEGEND Release 5.0:
Table of Contents

Advertisement

MERLIN LEGEND Communications System Release 5.0
System Programming 555-650-111
2
Programming with SPM
Using SPM
Restore is terminated under the following conditions:
If fewer boards are listed on the disk than on the control unit
If any real board is out of sequence with the boards listed on the disk
If phantom boards are not listed last
If the operating mode of the system being restored is Hybrid/PBX, but the
control unit processor module has been modified to operate only in Key
mode
A successful restore is followed automatically by a Restart (cold start)
!
Follow the steps below to perform a restore.
At the SPM Main Menu, press
 
SPM Main Menu
Menu: Select Function
Sys Program
Backup
Boards
Print Opts
Monitor
Follow the instructions for a floppy or a hard disk.
 
A second window appears which displays the
listing for C:\spm\backup.
If you are performing a Restore with a file saved on a floppy disk, go to
Step 3.
If you are performing a Restore with a file saved on the hard disk, go to
Step 4.
WARNING:
An unsuccessful or terminated restore results in a System Erase
(frigid start). All calls are dropped. The system configuration is
erased. All system programming is lost and the system returns to the
factory settings. If the restore is being done remotely, the connection
is dropped immediately. If this happens, attempt to reconnect to the
control unit and immediately perform another restore. If this is not
successful, programming must be restored on site.
to select
Maintenance
Restore
Pass-Thru
Password
Language
.
Restore
option and a directory
GOTO FLOPPY
Issue 1
June 1997
Page 2-45

Advertisement

Table of Contents
loading