MERLIN LEGEND Communications System Release 5.0
System Programming 555-650-111
4
Programming Procedures
Telephones
PC Procedure
ARS Restriction Level For Extensions
Use this procedure to assign an ARS restriction level to an extension. Only
outgoing calls are affected; users can receive inside, local, and toll calls on
restricted telephones and can join any type of call in progress. In order to use a
route, a caller at an extension must have a Restriction Level that is equal to or
greater than the Facility Restriction Level (FRL) for the route. The restriction level
assigned to extensions is opposite to the FRL assigned to routes, where 0 is the
most and 6 is the least restrictive.
Summary: Assigning ARS Restriction Level
for an Extension
Programmable by
Mode
Idle Condition
Planning Form
Factory Setting
Valid Entries
Inspect
Copy Option
Console Procedure
PC Procdure
To copy to a single extension:
Type copy from ext. no.
copy to ext. no.
To copy to a block of extensions:
Type copy from ext. no.
copy no. in copy to block
System Manager
Hybrid/PBX only
Not required
Form 4b, Analog Multiline Telephone
Form 4d, MLX Telephone
Form 4e, MFM Adjunct: MLX Telephone
Form 4f, Tip/Ring Equipment
Form 5a, Direct-Line Console (DLC): Analog
Form 5b, Direct-Line Console (DLC): Digital
Form 5c, MFM Adjunct: DLC
Form 6g, Call Restriction Assignments and Lists
3 (ports assigned as VMI Generic or VMI Integrated are
maximally restricted with an FRL of 0)
0-6, (0 is most restrictive and 6 is least restrictive)
No
No
More
Extensions
no.
Drop
Enter
Type ext. no.
restriction level
4
4
Dial ext.
ARS Restrict
Dial restriction level
Issue 1
June 1997
Page 4-247