MERLIN LEGEND Communications System Release 5.0
System Programming 555-650-111
3
Common Administrative Procedures
System Features
Console/Display Instructions
Return to the System Programming menu.
 
Select
two times.
Exit

Recall Timer

Use this procedure to designate the length of the timed flash that is sent when
Recall is used to disconnect a call and to get a new dial tone without hanging up.
Both the interval of the timed flash and the way that Recall works depend on the
type of telephone and system operating mode.
The recall timer should be reset if multiline telephone users experience either of
the following problems:
Nothing happens when the user presses the Recall button on an outside
call. This indicates that the interval is too short and should be increased to
650 milliseconds or one second.
In a system operating in Behind Switch mode, the call is disconnected
when the user presses the Recall button on an outside call. This indicates
that the interval is too long and should be decreased to 350 milliseconds.
Summary: Recall Timer
Programmable by
Mode
Idle Condition
Planning Form
Factory Setting
Valid Entries
Inspect
Copy Option
Console Procedure
PC Procedure
Additional Information
System Manager
All
Not required
Form 8a, System Features
450 ms
350 ms, 450 ms, 650 ms, 1 second
No
No
More
Options
RecallTimer
time
Enter
Exit
Select time
3
3
Select
Issue 1
June 1997
Page 3-195