Lucent Technologies MERLIN LEGEND Release 5.0 System Programming Manual page 492

Communications system
Hide thumbs Also See for MERLIN LEGEND Release 5.0:
Table of Contents

Advertisement

MERLIN LEGEND Communications System Release 5.0
System Programming 555-650-111
4
Programming Procedures
DS1 Facilities
Console/Display Instructions
Return to the System Programming menu.
 
Select
four times.
Exit
Answer Supervision Timing Procedure
Console Display/Instructions
Erase the current answer supervision time ( nnnn ) .
 
S56 Data
Enter AnsSupervisionTime
(20-4800, increment 20)
nnnn
Backspace
Exit
Enter the new answer supervision time
 
( nnnn = 20 to 4800 ms, in increments of 20 ms).
Dial or type [ nnnn ].
Continue to assign answer supervision time to another channel or go to Step 4.
 
Select
.
Next
Save your entry.
 
Select
.
Enter
Return to the System Programming menu.
 
Select
four times.
Exit
Disconnect Timing Procedure
Console/Display Instructions
Erase the current disconnect time ( nnnn ).
 
S56 Data
Enter Disconnect time
(140-4800)
nnnn
Backspace
Exit
Additional Information
Additional Information
xx = number entered in Step 1
Ch xx :
Next
Press Drop.
Enter
Additional Information
xx = number entered in Step 1
Ch xx :
Next
Press Drop.
Enter
Return to Step 1. The next channel will be
displayed on Line 1.
Issue 1
June 1997
Page 4-85