Automatic Maintenance Busy

Automatic Maintenance Busy allows the system to take a malfunctioning trunk out
of service for outgoing calls (incoming calls are never blocked). This prevents
faulty outside facilities from causing disruptions in outgoing calling patterns.
For optimal performance, enable Automatic Maintenance Busy for Hybrid/PBX
systems with pooled trunks.
NOTE:
NOTE:
NOTE:
No more than half of the trunks in a trunk pool are allowed to be placed in
the maintenance busy state at one time unless the central office has failed
to disconnect a trunk (which prevents anyone from using that trunk) or an
entire trunk module is manually taken out of use (a maintenance-busy state
deliberately caused by the user).
MaintenBusy
Date
Time
Back/Restore
Select
Hybrid/PBX
Enter
or
,
Key
,
.
BehndSwtch
The session is terminated and the system
restarts. You must enter system programming
again to continue.