Ds1 Facilities - Lucent Technologies MERLIN LEGEND Release 5.0 System Programming Manual

Communications system
Hide thumbs Also See for MERLIN LEGEND Release 5.0:
Table of Contents

Advertisement

MERLIN LEGEND Communications System Release 5.0
System Programming 555-650-111
4
Programming Procedures

DS1 Facilities

Console/Display Instructions
Save your entry.
 
Select
.
Enter
Return to the System Programming menu.
 
Select
three times.
Exit
DS1 Facilities
Use the procedures in this section to program the following options for DS1
(digital signal level 1) facilities (T1 or PRI) connected to a 100D (DS1) module:
Type of DS1 facility
Switched 56 Dial Plan Routing
Frame Format
Zero Code Suppression
Signaling Mode
Line Compensation
Channel Service Unit
Type of DS1 Facility
Use this procedure to specify the type of facility (T1 or PRI) connected to a 100D
(DS1) module. If T1 type is programmed, and the channels are used for emulation
and/or AT&T Switched Network (ASN), you must specify the type of channel
emulation.
If the type is T1 and the type of channel emulation is tie trunk, you must specify
whether the lines/trunks are TIE-PBX, Toll, or Switched 56 Data service. The valid
settings are as follows:
TIE-PBX. Select when emulated tie trunks are used to connect to another
communications system (such as PBX or Centrex). The transmit/receive
parameter is set to 0/4.
Toll. Select when emulated tie trunks are used for ASN services (such as
Megacom , Megacom 800, or Software Defined Network). The
transmit/receive parameter is set to 0/6.
— T1
— ISDN (Integrated Services Digital Network) Primary Rate Interface
(PRI)
Additional Information
4
4
Issue 1
June 1997
Page 4-73