Lucent Technologies MERLIN LEGEND Release 5.0 System Programming Manual page 622

Communications system
Hide thumbs Also See for MERLIN LEGEND Release 5.0:
Table of Contents

Advertisement

MERLIN LEGEND Communications System Release 5.0
System Programming 555-650-111
4
Programming Procedures
BRI Facilities
Procedure: Timers
Table 4-4.
Timers
Timer/Count
er
Purpose
T200 Timer
maximum response
time
T203 Timer
maximum time
T303 Timer
Set up timeout
T305 Timer
Disconnect timeout
T308 Timer
Release timeout
Console Display/Instructions
Select the Lines and Trunks menu.
 
System Programming:
Make a selection
System
SysRenumber
Operator
LinesTrunks
_
Exit
Go to the second screen of the Lines and Trunks menu.
 
Lines and Trunks:
Make a selection
LS/GS/DS1
TIE Lines
TT/LS Disc
DID
Exit
Select BRI.
 
Lines and Trunks:
Make a selection
HoldDiscnct
PrncipalUsr
QCC Prior
QCC Oper
Exit
Factory
Setting
1000 ms
33 seconds
4 seconds
30 seconds
4 seconds
Additional Information
>
Extensions
Options
Tables
AuxEquip
NightSrvce
>
PRI
Copy
RemoteAccss
Pools
Press More.
Toll Type
>
LS-ID Delay
ClockSync
BRI
_
4
Valid Range
Increments
500 to 5000 ms
500 ms
10 to 255 sec
1 sec
2 to 10 sec
1 sec
2 to 60 sec
1 sec
2 to 10 sec
1 sec
Issue 1
June 1997
Page 4-215