MERLIN LEGEND Communications System Release 5.0
System Programming 555-650-111
4
Programming Procedures
Tie Trunks
Console Display/Instructions
Erase the current number of milliseconds ( nnnn ).
 
Trunk xxxx :
Enter AnsSupervisionTime
(20-4800, increment 20)
nnnn
Backspace
Exit
Enter the answer supervision time ( nnnn = 0 to 4800 ms, increments of 20).
 
Trunk xxxx :
Enter AnsSupervisionTime
(20-4800, increment 20)
Backspace
Exit
Continue to assign the supervision time to another trunk or go to Step 9.
 
Select
.
Next
Save your entry.
 
Select
.
Enter
Return to the System Programming menu.
 
Select
twice.
Exit

Disconnect Time

Use this procedure to specify the tie trunk disconnect time limit in milliseconds.
Summary: Disconnect Time
Programmable by
Mode
Idle Condition
Planning Form
Additional Information
xxxx = trunk entered in Step 4
Next
Enter
Press Drop.
xxxx = trunk entered in Step 4
Next
Dial or type [ nnnn ].
Enter
System Manager
All
Not required
Form 3c, Incoming Trunks: Tie
Return to Step 6. The next trunk will be dis-
played on Line 1.
4
4
Issue 1
June 1997
Page 4-120
PC
+