4
Programming Procedures
Optional Group Features
Factory Setting
Valid Entries
Inspect
Copy Option
Console Procedure
PC Procedure
Group Calling Message-Waiting Indicator
Use this procedure to designate the extension to receive message-waiting
indications (MWIs) for the calling group.
Only one extension can be designated as a message-waiting receiver for each
calling group; however, more than one calling group can use the same
message-waiting receiver. The extension assigned as a message-waiting receiver
does not have to be a member of the calling group.
Message-waiting indications cannot be sent to the extension assigned to the
group unless this option is programmed. The message-waiting receiver cannot
distinguish between messages left for the calling group and personal messages.
Summary: Group Calling Message-Waiting
Indicator
Programmable by
Mode
Idle Condition
Planning Form
Factory Setting
Valid Entries
Inspect
Copy Option
Overflow coverage: none
Threshold: 1 call
Timeout: 0 sec
Overflow coverage: Backup extension number
Threshold: 1 to 99 calls
Timeout: 0 to 900 seconds
No
No
More
Extensions
calling group ext. no.
no.
Enter
Number Based Overflow
calls
Enter
Time Based Overflow
seconds
Enter
Exit
no.
Type backup ext. no.
Type no. of call
seconds
System Manager
All
Not required
Form 7d, Group Calling
No message-waiting receiver assigned
Extension number
No
No
Grp Calling
Overflow
Dial ext.
Enter
Drop
Drop
Exit
Type calling group ext.
+
4
4
Issue 1
June 1997
Page 4-271
Dial
Dial no. of
Dial no. of
+
Type no. of