Programming Procedures
Memory Card
Card Missing or Card Not Inserted Correctly
Memory Card Restore:
Verify that Memory Card
has been inserted
correctly.
Exit
The memory card is either not inserted or inserted incorrectly. The restore is
aborted. You must reinsert the card and repeat the restore procedure. This screen
may also appear if the wrong type of memory card is inserted and a restore is
requested within one minute of insertion. Verify that the card is a translation
memory card.
Card Removed after Confirmation
Memory Card Restore:
RESTORE IS CANCELED.
System is DOWN.
The memory card was removed from the PCMCIA interface slot while the restore
was in progress. The restore is aborted and the system performs a System Erase
(frigid start). You must reinsert the memory card and repeat the restore
procedure.
Wrong System Programming Port
Restore n :
Change Sys Programming
Port to Extension xxxx
before Restoring.
Exit
The system programming port is not set to the same system programming port as
that set in the backup file. The restore is aborted. Use the Inspect feature to view
the port of the file on the card. Change the system programming port to match the
port shown on the card (see "System Programming Position Assignment") and
repeat the restore procedure.
4
4
4
n = filename selected
xxxx = system programming port
extension