4
Programming Procedures
BRI Facilities
Console Display/Instructions
Erase the current DN.
 
Line xxx :
Enter DN
xxxxxxxxxx
Backspace
Exit
Enter the new DN.
 
Dial or type [ xxxxxxxxxx ].
Save your entry.
 
Select
.
Enter
Return to the System Programming menu.
 
Select
three times.
Exit
Timers
Use this procedure to set timer thresholds.
!
If the network does not respond before the programmed time, the system takes
the appropriate corrective action.
The timers are listed below.
T200 Timer. Minimum time that the link layer waits for an
acknowledgement of a message sent from the communications system to
the network.
T203 Timer. Maximum time that the link layer can remain inactive.
T303 Timer. Times the delay in network response when the
communications system sends a setup message to initiate an outgoing
call.
Additional Information
xxx = line number selected in Step x.
Next
Press Drop.
Enter
CAUTION:
The factory settings for these thresholds are standard and rarely
need to be changed. If you are not sure of the correct timer and
threshold settings for your BRI lines and trunks, check with your
Lucent Technologies representative before you make a change.
Incorrect settings can cause your BRI lines and trunks to malfunction.
4
Issue 1
June 1997
Page 4-213