Display Poe-Power Alarm - H3C S7500E Series Command Manual

Hide thumbs Also See for S7500E Series:
Table of Contents

Advertisement

Command Manual – PoE
H3C S7500E Series Ethernet Switches
Output AC Current A Alarm
Output AC Current B Alarm
Output AC Current C Alarm
Module 1:
Volt Phase AB Alarm
Volt Phase BC Alarm
Volt Phase CA Alarm
Module 2:
Volt Phase AB Alarm
Volt Phase BC Alarm
Volt Phase CA Alarm
Table 1-8 Description on the fields of display poe-power ac-input state
Module Number
Output AC Current
A/B/C Alarm
Volt Phase AB/BC/CA
Alarm

1.1.10 display poe-power alarm

Syntax
display poe-power alarm
View
Any view
Parameters
None
Description
Use the display poe-power alarm command to display the alarm information of the
PoE power.
Field
Number of modules that a power supply unit (PSU)
contains
Output three-phase AC voltage state:
Normal: The voltage is normal.
Under Limit: The voltage is below the lower limit.
Above Limit: The voltage is above the upper limit.
Lack Phase: A phase is lost.
Fuse Broken: The fuse is broken.
Switch Off: The switch is turned off.
Other Error: Other faults
AC voltage input state: Same as those of the output
three-phase AC current
Chapter 1 PoE Configuration Commands
: Normal
: Under Limit
: Lack Phase
: Above Limit
: Fuse Broken
: Switch Off
: Above Limit
: Fuse Broken
: Switch Off
Description
1-16