R&S ESU Series Operating Manual page 74

Emi test receiver
Table of Contents

Advertisement

R&S ESU
PEAKS
The PEAKS SUBRANGES softkey defines the search method with which maxima
SUBRANGES
are searched for within a scan.
PEAKS
SUBRANGES
Remote command:
MARGIN
The MARGIN softkey activates the entry field of the margin, i.e. of an additional
acceptance threshold for the determination of the peak list. The limit line currently
used is shifted by this amount for defining the maxima. The range of values is -200
dB to 200 dB.
Remote command:
FINAL
The FINAL MEAS TIME softkey activates the entry field of the time of final measure-
MEAS TIME
ment.
Remote command:
AUTOMATIC
The AUTOMATIC FINAL softkey selects the automatic routine for the final measure-
FINAL
ment. This routine is run according to the available frequency list without user inter-
action.
Remote command:
INTER
The INTERACTIVE softkey selects the following sequence for the final measure-
ACTIVE
ment:
A frequency from the frequency list is set together with the associated settings
from the corresponding partial scan.
The marker is set on this frequency in the scan diagram.
The final measurement sequence switches to the Interrupted status.
The signal can be exactly analyzed by modifying the receiver settings.
CONTINUE AT HOLD starts the actual final measurement, the receiver settings
being restored except the frequency.
The current frequency replaces the original one in the frequency list (drifting
interference sources)
Next frequency of frequency list.....
With the AUTOMATIC FINAL softkey in the CONTINUE FINAL MEAS submenu a
switchover can be made to the automatic mode before the measurement is
started anew.
Remote command:
Operating Manual 1302.6163.12 - 03
Determination of a specific number of peak values relative to the
limit lines with the level values being independent of their fre-
quency spectral distribution.
Generating subrange maxima, i.e. the interference spectrum is
further analyzed at frequencies with the highest interference level
of a frequency subrange.
:CALC:PEAK:METH SUBR|PEAK
:CALC:PEAK:MARG -200dB to 200dB
FME:TIME <num_value>
:FME:AUTO ON
:FME:AUTO OFF
Instrument Functions
Receiver Mode
4.43

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents