R&S ESU Series Operating Manual page 106

Emi test receiver
Table of Contents

Advertisement

R&S ESU
Table 4-1
File contents
Type;R&S ESU
Version;1.00;
Date;10.Nov 08;
Mode;Receiver;
Start;150000.000000;Hz
Stop;1000000000.000000;Hz
x-Axis;LOG;
Detector;AVERAGE;
Scan Count;1;
Transducer;;
Table 4-2
File contents
Scan 1:
Start;150000.000000;Hz
Stop;30000000.000000;Hz
Step; 4000.000000;Hz
RBW;9000.000000;Hz
Meas Time;0.001000;s
Auto Ranging;OFF;
RF Att;10.000000;dB
Auto Preamp;OFF;
Preamp;0.000000;dB
Scan 2:
Start;30000000.000000;Hz
Stop;1000000000.000000;Hz
Step; 50000.000000;Hz
RBW;120000.000000;Hz
Meas Time;0.000100;s
Auto Ranging;OFF;
RF Att;10.000000;dB
Auto Preamp;OFF;
Preamp;0.000000;dB
Operating Manual 1302.6163.12 - 03
Example – File header:
Description
Instrument model
Firmware version
Date of data set storage
Instrument mode
Start/stop of the display range.
Unit: Hz
Scaling of x-axis linear (LIN) or logarithmic (LOG)
Selected detector
MAXPEAK, MINPEAK, AVERAGE, RMS, QUASIPEAK
Scan count
Transducer name (if switched on)
Example – Data section of the file, Scan ranges
Description
Settings for scan range 1
Range 1 - start frequency in Hz
Range 1 – stop frequency in Hz
Range 1 - step size
Range 1 - resolution bandwidth
Range 1 - measurement time
Range 1 - Auto ranging on - or off
Range 1 - input attenuation
Range 1 - Auto Preamp on or off
Range 1 - preamplifier on (20dB) or off (0dB)
Settings for scan range 2
Range 2 - start frequency in Hz
Range 2 – stop frequency in Hz
Range 2 - step width
Range 2 - resolution bandwidth
Range 2 - measurement time
Range 2 - Auto ranging on - or off
Range 2 - input attenuation
Range 2 - Auto Preamp on or off
Range 2 - preamplifier on (20dB) or off (0dB)
Instrument Functions
Receiver Mode
4.75

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents