CALCulate<1|2>:MARKer<1...4>:FUNCtion:POWer:RESult:PHZ ON | OFF
This command switches the query response of the power measurement results in the indicated
measurement window between output of absolute values (OFF) and output referred to the
measurement bandwidth (ON).
The measurement results are output with CALCulate:MARKer:FUNCtion:POWer:RESult?
Parameter:
ON: Results output referred to measurement bandwidth.
OFF: Results output in absolute values.
Example of channel/adjacent channel measurement:
"SENS2:POW:ACH:ACP 3"
"SENS2:POW:ACH:BAND 30KHZ"
"SENS2:POW:ACH:BAND:ACH 40KHZ"
"SENS2:POW:ACH:BAND:ALT1 50KHZ"
"SENS2:POW:ACH:BAND:ALT2 60KHZ"
"SENS2:POW:ACH:SPAC 30KHZ"
"SENS2:POW:ACH:SPAC:ALT1 40KHZ"
"SENS2:POW:ACH:SPAC:ALT2 50KHZ"
"SENS2:POW:ACH:MODE ABS"
"CALC2:MARK:FUNC:POW:SEL ACP"
"INIT:CONT OFF"
"INIT;*WAI"
"CALC2:MARK:FUNC:POW:RES:PHZ ON"
"CALC2:MARK:FUNC:POW:RES? ACP"
If only the channel power is to be measured, all commands for defining the bandwidths of adjacent
channels as well as the channel spacings are not necessary. The number of adjacent channels is set
to 0 with SENS2:POW:ACH:ACP 0.
Characteristics: *RST value: -
SCPI: device-specific
Mode:
A-F
Operating Manual 1302.6163.12 - 03
Remote Control – Description of Commands
'Sets the number of adjacent channels in screen B to 3.
'Sets the bandwidth of the main channel to 30 kHz.
'Sets the bandwidth of all adjacent channels to 40 kHz.
'Sets the bandwidth of all alternate adjacent channels to
50 kHz.
'Sets the bandwidth of alternate adjacent channel 2 to
60 kHz.
'Sets the spacing between channel and adjacent chan-
nel as well as between all adjacent channels to 30 kHz.
'Sets the spacing between adjacent channel and alter-
nate adjacent channel as well as between all alternate
adjacent channels to 40 kHz.
'Sets the spacing between alternate adjacent channel 1
and alternate adjacent channel 2 to 50 kHz.
'Switches on absolute power measurement.
'Switches the adjacent channel power measurement in
screen B.
'Switches to single-sweep mode.
'Starts a sweep and waits for the end.
'Output of results referred to the channel bandwidth.
'Queries the result of the adjacent channel power mea-
surement in screen B referred to the channel bandwidth.
CALCulate Subsystem