4.5.10.1
Selection of Trace Function
The trace functions are subdivided as follows:
TRACE
SELECT TRACE
CLEAR/ WRITE
MAX HOLD
VIEW
BLANK
SCAN COUNT
DETECTOR
PEAK LIST
ON | OFF
Side menu
MIN HOLD
ASCII FILE EXPORT
DECIM SEP
COPY TRACE
The TRACE key opens a menu offering the setting options for the selected trace.
In this menu, the mode of representing the measured data in the frequency or time
domain in the 625 pixels of the display is determined. Upon start of the measure-
ment, each trace can be displayed either completely new or based on the previous
results.
Traces can be displayed, blanked and copied.
Operating Manual 1302.6163.12 - 03
Display mode of trace (CLEAR/WRITE, VIEW and BLANK)
Evaluation of the trace as a whole (AVERAGE, MAX HOLD and MIN HOLD)
Evaluation of individual pixels of a trace (MAX PEAK, MIN PEAK, QUASIPEAK,
AVERAGE and RMS).
!
MAX PEAK
MIN PEAK
QUASIPEAK
AVERAGE
RMS
Side menu
FINAL MAX PEAK
FINAL MIN PEAK
FINAL QUASIPEAK
FINAL AVERAGE
FINAL CISPR AV
FINAL RMS