R&S ESU Series Operating Manual page 552

Emi test receiver
Table of Contents

Advertisement

R&S ESU
DISPlay:BARGraph:LEVel:UPPer?
This command queries the maximum level of the bar graph.
Example:
":DISP:BARG:LEV:UPP?"
Characteristics: *RST value: --
SCPI: device-specific
Mode:
R
DISPlay:BARGraph:PHOLd ON | OFF
This command switches the indication of the maxhold value of the bar graph measurement on or off.
Example:
":DISP:BARG:PHOL ON"
Characteristics: *RST value: OFF
SCPI: device-specific
Mode:
R
DISPlay:BARGraph:PHOLd:RESet
This command resets the maxhold value of the numeric indication of the bar graph measurement.
Example:
":DISP:BARG:PHOL:RES"
Characteristics: *RST value: --
SCPI: device-specific
Mode:
R
This command is an event and thus has no *RST value and no query.
Operating Manual 1302.6163.12 - 03
Remote Control – Description of Commands
DISPlay Subsystem
6.113