"SENSe:LIST:POWer
performs a measurement sequence with the following settings:
Step
Freq.
Ref Level
[MHz]
1
935.2
-20 dBm
2
935.4
-20 dBm
3
935.6
-20 dBm
"SENSe:LIST:POWer?
performs the same measurement and returns the result list immediately after the last frequency point.
The measurement is performed in the time domain and therefore the span is set
to 0 Hz. If the time domain is abandoned, the function is automatically switched
off.
The measurement is not compatible with other measurements, especially as far
as marker, adjacent channel power measurement or statistics are concerned.
The corresponding commands thus automatically deactivate the function.
The function is only available in remote control. It is deactivated when switching
the instrument back to LOCAL.
Characteristics: *RST value: --
SCPI: device-specific
Mode:
A
6.186
935.2MHz,-20dBm,10dB,OFF,NORM,1MHz,3MHz,434us,0,
935.4MHz,-20dBm,10dB,OFF,CFIL,30kHz,100kHz,434us,0,
935.6MHz,-20dBm,10dB,OFF,CFIL,30kHz,100kHz,434us,0"
RF Att
el Att
Filter type
10 dB
OFF
Normal
10 dB
OFF
Channel
10 dB
OFF
Channel
935.2MHz,-20dBm,10dB,OFF,NORM,1MHz,3MHz,434us,0,
935.4MHz,-20dBm,10dB,OFF,CFIL,30kHz,100kHz,434us,0,
935.6MHz,-20dBm,10dB,OFF,CFIL,30kHz,100kHz,434us,0"
Remote Control – Description of Commands
RBW
VBW
Meas Time
1 MHz
3 MHz
434 us
30 kHz
100 kHz
434 us
30 kHz
100 kHz
434 us
Operating Manual 1302.6163.12 - 03
SENSe Subsystem
TRG Level
(reserved)
0
0
0