Emi test receiver
Table of Contents

Advertisement

R&S ESU
LIST EVAL
Activates or deactivates the list evaluation.
(ON OFF)
A peak search evaluation is performed automatically during the measurement. The
results are displayed in a table below the measurement diagram.
By default, the list evaluation is active.
The evaluation table shows the following results:
frequency range
frequency of the absolute peak power in the corresponding range.
frequency of the peak power in the corresponding range.
difference between the limit line and the current power level in dB.
result of the limit check (color and an asterisk indicate a failed limit check).
The trace, limit line, result of the limit check and the channel power of the reference
range are displayed in full screen, too, if the LIST EVALUATION is inactive.
Remote command:
MARGIN
Opens an edit dialog box to enter the margin used for the limit check/peak search.
LOAD
Opens a dialog box to select a customized standard in the *.xml file format. Refer to
STANDARD
the description of
ment" on page 4.223
files" on page 4.228
standards.
RESTORE
Restores the original *.xml files that came with the R&S ESU. Note that files of the
STANDARDS
same name are overwritten.
Operating Manual 1302.6163.12 - 03
CALC:ESP:PSE:AUTO ON
"Provided XML Files for the Spectrum Emission Mask Measure-
and
"Format Description of Spectrum Emission Mask XML
for more information on provided standards and customizing
Instrument Functions
Analyzer Mode
4.239

Hide quick links: