6.5.8
CALCulate:THReshold Subsystem
The CALCulate:THReshold subsystem controls the threshold value for the maximum/minimum search of
markers. The measurement windows are selected by CALCulate 1 (screen A) or 2 (screen B).
CALCulate<1|2>:DLINe<1|2> MINimum .. MAXimum (depending on current unit)
This command defines the position of Display Line 1 or 2. These lines enable the user to mark any
levels in the diagram. The unit depends on the setting made with CALC:UNIT.
Example:
"CALC:DLIN -20dBm"
Characteristics: *RST value: - (STATe to OFF)
SCPI: device-specific
Mode:
R, A
CALCulate<1|2>:DLINe<1|2>:STATe ON | OFF
This command switches Display Line 1 or 2 (level lines) on or off.
Example:
"CALC:DLIN2:STAT OFF"
Characteristics: *RST value: OFF
SCPI: device-specific
Mode:
R, A
CALCulate<1|2>:THReshold MINimum to MAXimum (depending on current unit)
This command defines the threshold value for the maximum/minimum search of markers with marker
search functions MAX PEAK, NEXT PEAK, etc. in the selected measurement window. The associated
display line is automatically switched on.
Example:
"CALC:THR -82DBM"
'Sets the threshold value for screen A to -82 dBm.
Characteristics: *RST value: - (STATe to OFF)
SCPI: device-specific
Mode:
R, A
CALCulate<1|2>:THReshold:STATe ON | OFF
This command switches on or off the threshold line in the selected measurement window. The unit
depends on the setting performed with CALC:UNIT.
Example:
"CALC2:THR:STAT ON"
'Switches on the threshold line in screen B.
Characteristics: *RST value: OFF
SCPI: device-specific
Mode:
R, A
Operating Manual 1302.6163.12 - 03