R&S ESU Series Operating Manual page 263

Emi test receiver
Table of Contents

Advertisement

R&S ESU
Child Node
Attribute
DefaultLimitFailMode
Table 4-5
Child Node
Attribute
Index
Name
ShortName
ChannelType
WeightingFilter
Type
RollOfffactor
Bandwidth
FrequencyRange
Start
Stop
Limit
Start
Value
Unit
Stop
Value
Unit
LimitFailMode
4.232
Value
Absolute | Relative |
Absolute and Relative |
Absolute or Relative
Attributes and child nodes of the Range element (normal ranges)
Value
0...19
<string>
<string>
TX | Adjacent
RRC | CFILTer
0...1
<bandwidth in Hz>
<frequency in Hz>
<frequency in Hz>
<numeric value>
dBm/Hz | dBm | dBc | dBr | dB
<numeric value>
dBm/Hz | dBm | dBc | dBr | dB
Absolute | Relative | Absolute
and Relative | Absolute or
Relative
Instrument Functions
Parameter
Description
Parameter
Mandatory
Description
Indexes are continous
Yes
and have to start with 0
Name of the range
Only if
ReferenceChannel
contains a name and
range is reference
range
Short name of the range
No
Yes
Only if
ReferencePower
method is "TX
Channel Power" and
the range is the
reference range"
Type of weighting filter
Yes
Excess filter bandwidth
Only if filter type is
RRC
Filter bandwidth
Only if filter type is
RRC
Yes
Start value of the range
Yes
Stop value of the range
Yes
A Range must contain
Yes
exactly two limit nodes;
one of the limit nodes
has to have a relative
unit (e.g. dBc), the other
one must have an
absolute unit (e.g. dBm)
Power limit at start
Yes
frequency
Sets the unit of start
Yes
frequency
Power limit at stop
Yes
frequency
Sets the unit of stop
Yes
frequency
No (if specified, it has
to be equal to Default-
LimitFailMode
Operating Manual 1302.6163.12 - 03
Analyzer Mode
Mandatory
Yes

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents