6.3.4

X21/X22 EP terminals / temperature sensor Motor Module

Table 6- 3
X21/X22 EP terminals/temperature sensor
Terminal
1
2
3
4
Note
The function of the EP terminals is only available when Safety Integrated Basic Functions
are enabled.
NOTICE
Damage to motor in the event of an incorrectly connected KTY temperature sensor
If a KTY temperature sensor is connected with incorrect polarity, then it is not possible to
detect when the motor overheats. Overheating can cause damage to the motor.
• Connect the KTY temperature sensor with the correct polarity.
Note
The temperature sensor input is not needed if the motors feature an integrated DRIVE-CLiQ
interface or if temperature values are detected by means of a different module (SMC, SME).
Electric shock in the event of voltage flashovers at the temperature sensor
Voltage flashovers to the signal electronics can occur in motors without safe electrical
separation of the temperature sensors.
• Use temperature sensors that comply with the specifications relating to safe electrical
SINAMICS S120 Combi
Manual, 11/2017, 6SL3097-4AV00-0BP7
Function
+ Temp
- Temp
EP +24 V (Enable Pulses)
EP M1 (Enable Pulses)
WARNING
separation.
Motor Modules Booksize Compact as expansion axes
Technical specifications
Temperature sensors: KTY84–1C130 / PT1000 / PTC /
bimetallic switch with NC contact
Supply voltage: 24 VDC (20.4 ... 28.8 V)
Current consumption: 10 mA
Isolated input
The pulse inhibit function is only available when Safety
Integrated Basic Functions are enabled.
Type: Screw terminal 1 (Page 288)