Effects When The Limit Value Is Exceeded For Sg - Siemens SINUMERIK 840D Description Of Functions

Hide thumbs Also See for SINUMERIK 840D:
Table of Contents

Advertisement

3 Safety-Related Functions
3.5 Safely-reduced speed (SG)
3.5.4

Effects when the limit value is exceeded for SG

Configurable stop
When the selected speed limit is violated, a stop response configured in the
response
following machine data is generated:
For 611 digital
Timing when the limit
When the safely-reduced speed function is active, then the timing is as follows
value is violated
when the limit value is violated:
3-98
SINUMERIK 840D/SIMODRIVE 611 digital SINUMERIK Safety Integrated (FBSI) - Edition 11.03
Note
Changing the gear ratio, parking an axis or making changes to the mounted
equipment (e.g. replacing an encoder or motor) means decoupling the load
and encoder. This cannot be detected by the NC and drive. The "axis safely
referenced" state is then lost.
The user is responsible for ensuring that the axis is returned to the "axis
safely referenced" state if the functions "safe software limit switch" or "safe
cams" are used.
MD 36961: $MA_SAFE_VELO_STOP_MODE
MD 36963: $MA_SAFE_VELO_STOP_REACTION [ n ]
MD 1361: $MD_SAFE_VELO_STOP_MODE
MD 1363: $MD_SAFE_VELO_STOP_REACTION [ n ]
Note
An alarm is displayed (for 840D: 27011, for 611 digital: 300914). After the
cause of the error has been eliminated, the alarm can be acknowledged
with RESET. The monitoring function is then active again.
Depending on the selected monitoring clock cycle, the dynamic drives
may cause a brief increase in speed on the monitored axis/spindle before
the stop response sequence commences.
In traversing modes which use a transformation with singularity points
(e.g. 5-axis transformation and TRANSMIT), relatively high axial speeds
occur at these points. These speeds can initiate stop responses even
though the Cartesian motion of the tool center point (TCP) is below the
selected speed limit value.
The monitoring functions provided by SI are basically axis-specific. This
means that it is not possible to monitor the TCP directly.
© Siemens AG 2003 All Rights Reserved
11.03

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Simodrive 611 digital

Table of Contents