3. Press the AHHC control switch (A) on the control
handle to engage the AHHC. The header moves to the
current setpoint position.
4. Use the HEADER HEIGHT SETPOINT control dial (A)
as necessary to fine-tune the position.
Header In-Field Settings
NOTE:
Changes may have been made to the combine controls or display since this document was published. Refer to the
combine operator's manual for updates.
1. To view header group settings, touch the HEADER
icon (A) on the right side of the home screen.
2. The following information is displayed:
•
CURRENT POSITION of the header (B).
•
SETPOINT cut-off position (C) (indicated by red line)
•
HEADER symbol (D) – touch to adjust the setpoint
cut-off position using the scroll wheel on the right
side of the Tyton terminal.
•
CUT HEIGHT for the AHHC (E) – fine-tune with the
header height setpoint control dial on the header
control cluster.
•
HEADER WORKING WIDTH (F)
214683
OPERATION
Figure 3.308: AHHC on Control Handle
A
Figure 3.309: Header Control Cluster
F
G
Figure 3.310: Header Groups
196
A
E
B
D
C
A
Revision A