6. Position upper drive cover (B) onto the reel drive and
lower cover (C), and secure with six bolts (A).

Lubricating Auger Drive Chain

DANGER
To avoid bodily injury or death from unexpected start-up of machine, always stop engine and remove key
from ignition before leaving operator's seat for any reason.
Lubricate the auger drive chain every 100 hours. The auger drive chain can be lubricated with the float module
attached to the combine, but it is easier with the float module detached.
The auger drive cover consists of an upper and lower cover, and a metal inspection panel. Only the metal
inspection panel needs to be removed to grease the chain.
1. Remove four bolts (A) and the metal inspection
panel (B).
214683
MAINTENANCE AND SERVICING
Figure 5.20: Drive Cover
Figure 5.21: Auger Drive Inspection Panel