Checking Reel Height Sensor Voltages (Case IH)

NOTE:
Changes may have been made to the combine controls or display since this document was published. Refer to the
combine operator's manual for updates.
1. On the main page of the combine display, select
DIAGNOSTICS (A). The DIAGNOSTICS page opens.
2. Select SETTINGS tab (A). The SETTINGS page opens.
3. From the GROUP menu, select HEADER (B).
4. From the PARAMETER menu, select REEL VERTICAL
POSITION (C).
5. Select GRAPH tab (A). The REEL VERTICAL
POSITION graph displays.
6. Lower the reel to view the high voltage (B). The voltage
should be 4.1–4.5 V.
7. Raise the reel to view the low voltage (C). The voltage
should be 0.5–0.9 V.
8. If either voltage is out of range, refer to
Adjusting Reel Height Sensor, page