5. Use the < or > key to select CUTT. HEIGHT LIMITS,
and press the combine controls OK key.
6. Follow the procedure displayed on the screen to
program the upper and lower limits of the header into
the CEBIS.
7. Use the < or > key to select SENSITIVITY CAC, and
press the combine controls OK key.
NOTE:
Setting the sensitivity of the AHHC system affects the
reaction speed of the AHHC on the header.
8. Use the – key or the + key to change the setting of the
reaction speed, and press the combine controls OK key.
9. Use line (A) or value (B) to determine the sensitivity
setting.
NOTE:
The setting can be adjusted from 0–100%. When
sensitivity is adjusted to 0%, the signals from the
sensing bands have no effect on the automatic cutting
height adjustment. When sensitivity is adjusted to
100%, the signals from the sensing bands have
maximum effect on the automatic cutting height
adjustment. The recommended starting point is 50%.
NOTE:
If float was set heavier to complete the AHHC
calibration procedure, adjust to recommended
operating float after the calibration is complete.
214683
OPERATION
Figure 3.418: CLAAS Combine Display
Figure 3.419: CLAAS Combine Display
A
Figure 3.420: CLAAS Combine Display
243
B