6. Remove the bolts (A) and tee nuts securing the plastic
guide (B) to the auger, and remove the guide from
inside the auger.
7. Coat bolts (B) with medium-strength threadlocker
®
(Loctite
243 or equivalent), and then position plug (A)
into the hole from inside the auger, and secure with two
bolts (B) and tee nuts. Torque to 8.5 Nm (75 lbf∙in).
8. Coat bolts (A) with medium-strength threadlocker
®
(Loctite
243 or equivalent) and replace the access
cover (B) using the bolts to secure the access cover in
place. Torque bolts to 8.5 Nm (75 lbf∙in).
214683
MAINTENANCE AND SERVICING
Figure 5.69: Auger Finger Hole
Figure 5.70: Plug
Figure 5.71: Auger Access Hole Cover
430
A
B
A
B
A
B
Revision A