Case Ih 7010/8010, 7120/8120/9120, 7230/8230/9230 And 7240/8240/9240 Combines; Checking Voltage Range From The Combine Cab (Case 8010) - MacDon FlexDraper FD1 Series Operator's Manual

Combine header
Hide thumbs Also See for FlexDraper FD1 Series:
Table of Contents

Advertisement

3.8.5 Case IH 7010/8010, 7120/8120/9120, 7230/8230/9230 and
7240/8240/9240 Combines

Checking Voltage Range from the Combine Cab (Case 8010)

NOTE:
Changes may have been made to the combine controls or display since this document was published. Refer to the
combine operator's manual for updates.
CAUTION
Check to be sure all bystanders have cleared the area.
1. Position the header 150 mm (6 in.) above the ground, and unlock the float.
2. Check that float lock linkage is on down stops
(washer [A] cannot be moved) at both locations.
NOTE:
If the header is not on down stops during the next two
steps, the voltage may go out of range during operation
causing a malfunction of the AHHC system.
214683
OPERATION
Figure 3.209: Float Lock
150
A
Revision A