IMPORTANT:
To avoid damaging the new sensor, install sensor as
follows:
6. Position the new sensor (A) on the bracket (B).
7. Secure with two bolts (C) and nuts (D).
8. Attach sensor arm (A) to the sensor (B) and secure with
two screws (C).
9. Reconnect the wiring harness to the plug (B) on the
sensor.
10. Check the voltage range of the new sensor, and adjust
if necessary. Refer to:
Manually Checking Voltage Range: One-Sensor
System, page 127
Adjusting Voltage Limits: One-Sensor System, page
131
214683
OPERATION
Figure 3.172: AHHC Sensor
B
Figure 3.173: AHHC Sensor
134
A
D
B
A
C
C
Revision A