7. Select the AHHC SENSING option.
8. Press the icon that resembles an arrow in a box (A).
The AHHC SENSING menu appears and five screens
of information are displayed.
9. Press icon (A) until it reads Page 5 near the top of the
screen and the following sensor readings appear:
• LEFT HEADER HEIGHT
• CENTER HEADER HEIGHT
• RIGHT HEADER HEIGHT
A reading is displayed for both left and right sensors.
On the MacDon header, there may be one sensor
located in the float indicator box (standard) or two
sensors located at the back of the float module side
frame (optional).
10. Ensure header float is unlocked.
11. Start the combine and fully lower feeder house to the ground.
NOTE:
You may need to hold the HEADER DOWN switch for a few seconds to ensure the feeder house is fully
lowered.
12. Check the sensor reading on the monitor.
13. If the sensor voltage is not within the low and high limits or if the range between the low and high limits is
insufficient, refer to
Adjusting Voltage Limits: One-Sensor System, page
214683