Refer to the following instructions for your specific combine model:
3.8.13 CLAAS 500 Series Combines, page 242
3.8.14 CLAAS 600 and 700 Series Combines, page 251
3.8.15 New Holland Combines (CR/CX Series-Pre-2015 Model Year), page 261
3.8.16 New Holland Combines (CR Series-Model Year 2015 and Later), page 271

3.8.1 Sensor Operation

The position sensors supplied with the auto header height control (AHHC) system are hall-effect sensors
containing sealed connectors. Normal operating signal voltages for the sensors fall between 10% (0.5 VDC) and
90% (4.5 VDC). An increase in sensor voltage correlates to an increase in header height.
Sensor errors result in a 0 V signal, indicating a faulty sensor or incorrect supply voltage.
214683