6. Press the NEXT PAGE icon (A) to cycle to page 3.
7. Lower the reel to view the low voltage (B) The voltage
should be 0.5–0.9 V.
8. Raise the reel to view the high voltage (A). The voltage
should be 4.1–4.5 V.
9. If either voltage is not within the correct range, refer to
Checking and Adjusting Reel Height Sensor, page

Calibrating Reel Height Sensor (John Deere S and T Series)

This procedure applies only to model year 2015 and later John Deere S and T Series combines.
NOTE:
Changes may have been made to the combine controls or display since this document was published. Refer to the
combine operator's manual for updates.
To calibrate reel height, follow these steps:
214683
OPERATION
Figure 3.378: John Deere Combine Display
96.
Figure 3.379: John Deere Combine Display
227
B
A
A
Revision A