Curr Snr Margin(dB/10)
Curr Atn(dB/10)
CurrAttainable Rate(bps)
Curr Output Pwr(dB/10)
AturGsConfig
Chan Perf CD
Chan Perf CU
Chan Perf BE
Overhead Channel
System Vendor ID
ATU-R Self Test Result
ATUR G9941 Vendor ID
270
signal, and initialization errors, cannot be determined.
Noise Margin as seen by this ATU, with respect to its received
signal, in tenth dB.
Measured difference in the total power transmitted by the peer
ATU, and the total power received by this ATU.
Indicates the maximum currently attainable data rate by the ATU.
This value will be equal to, or greater than, the current line rate.
Measured total output power transmitted by this ATU.This is the
measurement that was reported during the last activation
sequence.
The upstream and downstream ATU-R configuration data (EOC -
read 5 sec after data mode).
The far-end delineated total cell count performance parameter is a
count of the total number of cells passed through the cell
delineation and HEC function process, operating on the ATM Data
Path, while in the SYNC state. (Not available for ADSL)
The far-end user total cell count performance parameter is a count
of the total number of cells in the ATM Data Path delivered at the
V-C (for ATU-C) or TR (for ATUR) interface. (Not available for
ADSL)
The far-end idle bit error count performance parameter is a count
of the number of bit errors in the idle cell payload received in the
ATM Data Path at the far-end. (Not available for ADSL)
Indicates the Overhead Channel. This feature is not supported by
DSLPHY as yet.
Indicates the Vendor ID as inserted by the ATU-R in the Embedded
Operations Channel(ADSL). Typically identiies the ATU-R system
integrator which usually refers to the vendor of the smallest
field-replaceable unit. ATU-R System Vendor ID may not be the
same as ATU-R G.994.1 Vendor ID. For ADSL2, provides the
Vendor ID as inserted by the ATU-R in the Overhead Messages. It
is not available for ADSL. This is string of 8 octets containing 2
octet country code , 4 octet vendor id and 2 octet vendor revision
number.
Defines the ATU-R selftest result. The most significant octet is: 00
hex if the self-test passed or 01 hex if the self-test failed.
Interpretation of the other octets is vendor discretionary and can be
interpreted in combination with G.994.1 and system Vendor IDs.
Indicates the Vendor ID as inserted by the ATU-R in the G.994.1
CLR message.The G.994.1 Vendor ID typically identifies the
IDL series User Guide