Example:
$ create bridge static mcast vlanid 7 mcastaddr 00:30:4F:00:00:01 recvport 0
egressports 10 forbidegressports 20 SKIP 1
Output:
Verbose Mode On
Entry Created
VLan Index
Egress ports
Forbidden Egress ports : 20
Verbose Mode Off:
Entry Created
Output Fields:
Field
VLan Index
Mcast Address
Egress ports
Forbidden Egress ports
IP DSLAM
: 7
Mcast Address : 00:30:4F:00:00:01
: 10
Description
The VLAN id for this VLAN. In devices supporting "Shared Vlan for
multicast" capability, the information for a multicast MAC address is
shared across VLANS. Hence, vlanid is optional and can be passed
as zero or a valid vlanid value. In devices supporting "Independent
Vlan for multicast" capability, each vlan can have its own information
for a multicast MAC address. Hence, VLAN id is a mandatory
parameter and a valid value of vlanid must be passed. For the case
when the attribute "McastDeviceCapabilities" of MO "sysSizingTable"
has value "none", VLAN id is not required. This feature is not
supported for VLAN with vlanid as
GS_UNREGISTERED_VLANID.VLAN here means the 802.1q Vlan
in case of Native Vlan mode and Virtual Vlan in case of Stacked Vlan
Mode.
The destination multicast MAC address in a frame, to which the
filtering information of this entry applies.
The set of ports, to which frames received from a specific port and
destined for a specific Multicast MAC address must be forwarded. A
port may not be added in this set if it is already a member of the set of
ports in ForbiddenEgressPorts.
The set of ports, to which frames received from a specific port and
destined for a specific Multicast MAC address must not be forwarded,
regardless of any dynamic information. A port may not be added in
this set if it is already a member of the set of ports in EgressPorts.