mode auto | manual
Example:
$ get oam cc vc ifname aal5-0
Output:
ifName
------------------------------------------------------------
aal5-0
Manual activated
Output Fields:
Field
ifName
Mode
SourceOperStatus
SinkOperStatus
Initiator
References:
atm vc related commands.
atm port and statistics related commands.
atm oam loopback commands.
156
Type: Modify -- Optional
This specifies the activation/deactivation capability at a VCC.
Type: Modify -- Optional
Mode
SourceOperStatus SinkOperStatus Initiator
Description
This parameter specifies the interface, for which information is desired. In
case the field is not specified, then the information for all valid interfaces
should be displayed.
This specifies the activation/deactivation capability at a VCC.
This field specifies the current operational state of source point of the VCC.
This field specifies the current operational state of sink point of the VCC.
This field is valid only in auto mode and it specifies the current initiator of CC
Activation/Deactivation.
LOC
Self
IDL series User Guide