Installing the Fan Module

The Cisco Remote PHY Shelf 7200 system should not be operating without a Fan Tray installed for more than
Note
1-2 minutes or the system could experience thermal events, alarms, and potentially trip thermal protections that
would shut down RPD cards.
What to do next
• Visually check if the fans are working.
Installing the Fan Module
The Cisco Remote PHY Shelf 7200 Fan Module (HA-RPHY-FAN-MOD) is comprised of the fan, one handle
structure, EMI containment, and connector to interface to the Cisco Remote PHY Shelf 7200 Fan Tray.
The Fan Module is keyed so it can only install in the proper orientation to the Fan Tray.
To install the Fan Module, complete the following steps:
1. Align the Fan Module to the Fan Tray.
Figure 7: Fan Module
2. Push the Fan Module into the Fan Tray bay until there are tactile and audible clicks of the Fan Module
latches engaging to the Fan Tray top and bottom of the handle.
Installing the Cisco Remote PHY Shelf 7200
22