7.14.5
Access
Close Traverse...
Next step
FlexLine plus, Programs

Closing a Traverse

Close the traverse by selecting Close in the Sight Foresight! screen after a backsight
point measurement, but before the foresight point measurement.
Field
Description
F1 ...at Known
To close a traverse at a known station to a known closing point.
Station to
Use when setup on the closing station, and the coordinates for the
Known Closing
station and the closing point are known.
Point
1) Input the data for both points.
2) Measure to the closing point.
3) The results are displayed.
To close a traverse to a known closing point.
F2 ...to Known
Closing Point
Use when setup on an unknown station and only the coordinates
of the closing point are known.
1) Input the data for the point.
2) Measure to the closing point.
3) The results are displayed.
To close a traverse at a known station only.
F3 ...at Known
Station Only
Use when setup on the closing station and the coordinates for it
are known.
1) Input the data for the closing station.
2) The results are displayed.
F4 ...Leave
To leave the traverse open. There is no last traverse station.
Open
1) The results are displayed.
Select an option, from the Close Traverse... menu to proceed to the Traverse Results
screen.
F1 - F4
To select menu item.
If this method is chosen a distance measurement is manda-
tory.