Setup Method - Orientation & Height Transfer - Leica TM30 Series Field Manual

Hide thumbs Also See for TM30 Series:
Table of Contents

Advertisement

11.8
Setup Method - Orientation & Height Transfer
Requirements
Access
step-by-step
SETUP
Measure Target
Setup
For TPS1200+/TS30/TM30 the position coordinates of the station point are
required. The instrument is set up and oriented to one or more known backsight
targets.
For SmartStation the position coordinates of the station are unknown and are
determined with GPS real-time. The instrument is set up and oriented to one or
more known backsight targets.
For TPS1200+/TS30/TM30 and SmartStation the orientation is determined by
sighting to one or more known target points (maximum of ten target points). Only
angles or both angles and distances may be measured. The height of the station
point can also be derived from the target points.
Step
Description
1.
Press PROG to access the TPS1200+/TS30/TM30 Programs menu.
2.
Select and activate Setup to move to the first screen.
3.
Press CONT (F1) to access SETUP Station Setup.
4.
<Method:> Ensure that Ori & Ht Transfr is selected.
<Station Coord:> Select the source for the station coordinates.
<Station ID:> Enter/Select the instrument station.
<Instrument Ht:> Enter the height of the instrument station.
<Fixpoint Job:> Select the fixpoint job of the control/target points.
5.
<Fixpoints:> Select the method for measuring the control/target points.
Select Meas All Now if a "Standard" setup is required.
Select Add Points Later if an "On-the-Fly" setup is required.
6.
The geometric scale correction is displayed.
The correction displayed depends upon the options chosen in
CONFIGURE TPS Corrections, GeoPPM page:
if <Calc Scale: Automatically>, <Computd Scale:> is displayed.
if <Calc Scale: Manually>, <Current Scale:> is displayed.
7.
Press CONT (F1) to access SETUP Measure Target 1.