DI02-56
CHANGED BY
EFFECTIVE DATE
AFFECTED VIN
Notice
If the initialization of fuel pressure has not been
performed, the engine ECU controls new HP pump
with the stored offset value. This may cause the poor
engine output.
Install in the reverse order of removal and tighten the
fasteners with the specified tightening torque.
1. HP pump sprocket
2. 12-sided sprocket mounting bolt
3. HP pump bearing housing
4. HP pump (High Pressure Pump)
5. HP pump shaft
6. HP pump center nut
7. HP pump outer bolt
8. HP pump bearing shaft
9. Oil gallery
10. Bearing bushing
11. Gasket
* Tightening torque
Y220_02146
(M14 x 1.5 - 1EA)
(M8 x 55 - 3EA)
(M7 x 13 - 3EA)
Center nut
Outer bolt
Sprocket bolt
65 ± 5.0 Nm
24 ± 2.4 Nm
20 Nm ± 90°