Download Print this page

INVT Goodrive350-19 Series Operation Manual page 99

Vfd for crane
Hide thumbs Also See for Goodrive350-19 Series:

Advertisement

Goodrive350-19 Series VFD for Crane
5.2 Commissioning horizontal moving
5.2.1 Wiring
Multi-step speed giving terminal 1
Multi-step speed giving terminal 2
Multi-step speed giving terminal 3
Coasting to stop
Note: If the wiring is performed according to Figure 5-12 Wiring for horizontal moving, most
VFD parameters need no adjustment. If the onsite function terminals are inconsistent with the
terminals shown in the figure, adjust the input and output terminal functions according to the
actual wiring after selecting this application macro.
5.2.2 Commissioning procedure
1.
Check the wiring and ensure the wiring is proper.
2.
Set P00.18=1 to restore to default settings.
3.
Set motor nameplate parameters in P02.
4.
Set P90.00=3 to select the horizontal moving application macro.
5.
Perform low-speed trial run.
5.2.3 Horizontal moving application macro parameters (P90.00=3)
Function code
P00.01
R
S
T
FWD run
REV run
Fault reset
Figure 5-12 Wiring for horizontal moving
Name
Channel of running
commands
Braking resistor
(+)
R
S
VFD
T
S1
S2
S4
COM
PW
+24V
S5
S6
S7
S8
COM
PW
+24V
IO card
EC-IO-502-00
Setting
1
-87-
Commissioning guidelines
PB
U
V
W
PE
RO1A
RO1B
VFD fault output
RO1C
RO2A
RO2B
Brake output
RO2C
Remarks
Terminal
M
3~

Advertisement

loading
Need help?

Need help?

Do you have a question about the Goodrive350-19 Series and is the answer not in the manual?