Goodrive350-19 Series VFD for Crane
Function
Name
code
Enabling
P90.04
brake-oriented
logic
Enabling forward
torque for
P90.05
reverse-running
start/stop
Description
automatically performed.
5: Switch to SVC1 control (open-loop vector
control 1)
When P90.03=5, P90.00 must be 2, while
P90.01 must be 1; alternatively, P90.00 must be
11, while P90.01 must be 12. Only control mode
can be switched, and the S terminal selects
function 62 and takes effect.
Note: When P90.03=1 or 2, function macros
can
be
switched
communication, of which mode is set by
P08.31.
0–1
0: The brake is controlled by an external
controller.
1: The brake is controlled by the VFD.
0x00–0x11
Ones place: indicates whether to enable
forward torque for reverse-running start
0: Disable
(The reverse-running start direction complies
with the command.)
1: Enable
(The reverse-running start direction is always
the forward-running direction.)
REV
Start FWD torque disabling
Run
REV
command
Output
frequency
Tens place: indicates whether to enable forward
torque for reverse-running stop
0: Disable (The reverse-running stop direction
is consistent with the command.)
1: Enable (The reverse-running stop direction is
always the forward-running direction.)
-301-
over
through
REV
Start FWD torque enabling
Run
command
REV
Output
frequency
Function parameters
Default Modify
◎
0
◎
0x00