Vfd for crane
Hide thumbs Also See for Goodrive350-19 Series:

Advertisement

Goodrive350-19 Series VFD for Crane
3.
Set motor parameters in P02.
4.
Set P05.01=10 and P05.02=11 to specify the UP/DOWN terminals.
5.
Set P08.44 to set terminal control validity, and set P08.45 and P08.46 to set the
increase/decrease change rate of the UP/DOWN terminal frequency.
6.
Press UP/DOWN to run.
The following figure shows the electric potentiometer value curve.
DOWN
P00.03
5.4.3 Electric potentiometer commissioning parameters
Function
code
P00.03
Max. output frequency
P05.01
P05.02
UP/DOWN terminal
P08.44
UP
0
P08.45
Figure 5-17 Electric potentiometer commissioning
Table 5-7 Electric potentiometer commissioning parameters
Name
Function of S1
Function of S2
control setting
P08.46
Setting
Used to set the max. output frequency
50
of the VFD.
10
Increase frequency setting (UP)
11
Decrease frequency setting (DOWN)
0x000–0x221
Ones
selection
0:
The
UP/DOWN is valid.
0x000
1:
The
UP/DOWN is invalid.
Ones
selection
0: Valid only when P00.06 = 0 or
-105-
Commissioning guidelines
Remarks
place:
Frequency
setting
made
setting
made
place:
Frequency
setting
through
through
control