Goodrive350-19 Series VFD for Crane
Function
Name
code
User-defined
P90.02
application macro
setting
Switchover
selection for
P90.03
hoisting application
macros 1 and 2
Description
14: Tower crane slewing without using an eddy
current controller in closed-loop vector control
15: Tower crane slewing without using an eddy
current controller in space voltage vector
control
16–40: Reserved
0–3
1: Enter the settings of user-defined application
macro 1
2: Enter the settings of user-defined application
macro 2
3: Enter the settings of user-defined application
macro 3
0–5
0: No switchover
1: Switch from motor 1 to motor 2
When the S terminal selects function 35 and
takes
effect,
and
parameter is switched from P90.00 to P90.01,
and
motor
parameters
switched.
2: Switch from motor 1 to motor 3
When the S terminal selects function 88 and
takes
effect,
and
parameter is switched from P90.00 to P90.01,
and
motor
parameters
switched.
3: Switch from the master to the slave
When the S terminal selects function 72 and
takes
effect,
and
parameter is switched from P90.00 to P90.01,
and
the
master/slave
automatically performed.
4: Switch from the salve to the master
When the S terminal selects function 71 and
takes
effect,
and
parameter is switched from P90.00 to P90.01,
and
the
master/slave
-300-
P90.03=1,
the
macro
are
automatically
P90.03=2,
the
macro
are
automatically
P90.03=3,
the
macro
switchover
P90.03=4,
the
macro
switchover
Function parameters
Default Modify
◎
0
◎
0
is
is