Goodrive350-19 Series VFD for Crane
Function
code
P11.14
Speed deviation detection value
Enabling PI parameter
P23.15
switchover for start/stop in vector
P25.01
P25.02
P25.03
P25.04
Expansion card input terminal
P25.10
P26.04
RO3 output selection
P90.04
Enabling brake-oriented logic
P90.14
Forward brake release torque
P90.15
Reverse brake release torque
P90.16
Forward brake release frequency
P90.17
Reverse brake release frequency
P90.18
Forward brake closing frequency
P90.19
Reverse brake closing frequency
Delay before forward brake
P90.20
Torque verification fault detection
P90.30
Enabling the monitoring on brake
P90.31
Light/heavy load speed
P91.08
Load limit T1 in stepped speed
P91.18
limit upward running
Restricted frequency f1 in
P91.19
stepped speed limit upward
Load limit T2 in stepped speed
P91.20
limit upward running
Restricted frequency f2 in
P91.21
stepped speed limit upward
Name
mode
Function of S5
Function of S6
Function of S7
Function of S8
polarity
release
time
status
regulation selection
running
Setting
20.0%
1
75
16
17
85
Enable brake detection
0x01
57
1
The brake is controlled by the VFD.
Corresponding to the motor rated
30.0%
Corresponding to the motor rated
20.0%
0.40Hz
0.40Hz
0.20Hz
0.20Hz
0.100s
2.000s
Enable the brake current monitoring
1
(and brake feedback detection).
3
65.0%
(Common functions for tower cranes
55.00Hz
need to be set based on
40.0%
75.00Hz
-56-
Commissioning guidelines
Remarks
/
Enable
Brake feedback signal
Multi-step speed 1
Multi-step speed 2
/
Brake failure alarm
torque
torque
/
/
/
/
/
/
Stepped speed limit
requirements.)