Download Print this page

INVT Goodrive350-19 Series Operation Manual page 377

Vfd for crane
Hide thumbs Also See for Goodrive350-19 Series:

Advertisement

Goodrive350-19 Series VFD for Crane
8.6.5 Motor overheating
Unusual heating of the
motor
Whether the motor
parameters are set
correctly?
Whether parameter
autotuning is
performed?
No
Whether the VFD runs at a
low speed all the time?
Whether it is a variable-
frequency motor?
Whether the load is
too heavy?
Whether the three
phases of the motor are
balanced?
Whether the carrier
frequency is too low?
Whether the motor
cable is too long?
If it is a VFD fault, contact
our company
No
Yes
No
Yes
Yes
No
frequency motor
Yes
Yes
No
No
Yes
Yes
No
Yes
No
-365-
Troubleshooting
Set the motor
parameters
correctly
Parameter
autotune
Use a variable-
Reduce the
load
Replace the
motor
Set the carrier
frequency
properly
Add an output
filter

Advertisement

loading
Need help?

Need help?

Do you have a question about the Goodrive350-19 Series and is the answer not in the manual?