Goodrive350-19 Series VFD for Crane
Function
Name
code
Slave positive
P28.08
speed deviation
window upper limit
Slave negative
speed deviation
P28.09
window lower limit
Slave rotation
P28.10
speed regulation
coefficient Kb
CAN slave torque
P28.13
offset
Master/slave
holding brake
P28.14
synchronization
control
Master/slave brake
release
P28.15
synchronization
timeout time
Master/slave brake
closing
P28.16
synchronization
timeout time
P28.18
Slave torque
Description
can be enabled.
0.00–50.00Hz
When the actual speed is higher than the
reference speed, if the actual speed is higher
than (Reference speed + P28.08) and exceeds
this upper limit, the speed has to be adjusted.
0.00–50.00Hz
When the actual speed is lower than the
reference speed, if the actual speed is lower
than (Reference speed - P28.09) and the
window lower limit, the speed has to be
adjusted.
0–50000
Applicable only in master/slave mode 4, for
slave rotation speed regulation
-100.0–100.0%
0x00–0x11
Ones place: Brake release synchronization
0: Invalid
1: Valid
Tens place: Brake closing synchronization
0: Invalid
1: Valid
Note: In a master/slave mode, when the
function specified by P28.14 is enabled, the
master and slave must be the same in brake
release
frequency
frequency.
0.00–30.00s
0.00–30.00s
0–1
-291-
and
brake
closing
Function parameters
Default Modify
○
5.00Hz
○
5.00Hz
○
100
○
0.0%
○
0x11
○
1.00s
○
2.00s
○
0
Need help?
Do you have a question about the Goodrive350-19 Series and is the answer not in the manual?